Gen 3 SET-UP MENU

REM  Set the duration for mists triggered by the remote transmitter.  (Values from OFF to 120 seconds)

LRN  Program unit to recognize a specific remote transmitter.

  • Hold down Green ► button for 5 seconds and wait for countdown to begin.
  • Press and hold any button on the remote transmitter.
  • When DONE flashes in the display, the transmitter is programmed.

MAN*  Set the duration for mists triggered by a MANUAL MIST

NOZ*  Set the Number of nozzles in the circuit attached to the unit.  If Zone Kit installed, there are separate displays for NZ1 and NZ2.

AGT  Set duration for agitation sequence prior to each AUTO mist.  Set time of once daily off-cycle agitation.

RAG  Set duration for agitation prior to each REMOTE mist.

SEN  Turn (optional) wind sensor ON or OFF

WND  Set max wind speed (above which wind sensor reading inhibits mist.)

ALT  Set time (in seconds) that (optional) external alarm will sound prior to each scheduled and remote mist

ER0  Enable or disable ERRor Code 0.  Default is ON

ER2  Enable or disable ERRor Code 2.  Default is OFF

ER3  Enable or disable ERRor Code 3.  Default is ON

ER6  Enable or disable ERRor Code 6.  Default is ON

FM  Set flow meter type Brass (brS) or Plastic (PLS). Systems with serial numbers 403183 and higher are brass.

* For systems with zone kit installed, see Gen 3 Option:  Zone Kit

Gen 3 MAINTENANCE MENU

REFILL  “Virtually” fill the insecticide bottle.  Holding Green ► button for 5 seconds triggers routine that prompts user for insecticide/water MIX ratio, bottle size (in ounces), LEVEL of concentrate in bottle.

DRN  Drain.  Unit will mist until batch tank is empty and pressure falls.  Hold Green ► button for 5 seconds to trigger.

INS  Unit is in Inspection Mode.

  • Unit will fill with water and then mist for 5 minutes (refilling as necessary) without adding insecticide.
  • Hold Green ► button for 5 seconds to trigger.  If a Zone Kit is installed, there are separate inspection menus, INS1 and INS2.

CHG  Adds a full charge of concentrate to the batch tank. Holding Green ► button for 5 seconds initiates an extended DOSE routine which brings the full batch of fresh water to its target MIX ratio.

WINT  Winterizing step which holds inlet supply valve and agitation valve open for 30 seconds to allow any remaining trapped fluid to drain.  Hold Green ► button for 5 seconds to trigger.

FLT  Float switch diagnostic.  Displays “dn” if float switch is not positioned at top of travel.  Displays “UP” if it is.  See Gen 3:  Float Switch Test

FL tst  Flowmeter Diagnostic. Holding Green ► button triggers routine that determines whether flow of water to the unit is normal and whether flowmeter is working as it should.  See Gen 3:  Flowmeter Test

Gen 3 DATA MENU

DM  Daily Mist time (cumulative, in seconds)

MX  Maximum Daily Mist allowed (in seconds)

TMC  Total Mist Cycles since last reset* (*Reset by pressing Green ► button until value shows zero.)

TMM  Total Mist Minutes since last reset*

MMC  MANUAL MIST Cycles since last reset*

RMC  REMOTE MIST Cycles since last reset*

TMH  Total Mist Hours on unit.  May not be reset.

PRH  Cumulative dosing pump run time in hours.  May not be reset.

SPD  Wind speed as read by sensor

FL  Batch tank fill volume (in milliliters) following last mist

AFR  Average flow rate per nozzle in last zone misted (ml/min)

TF  Target fill volume (in milliliters)

NFR  Flow rate of average nozzle in circuit (in ml/min).  Used in error condition calculations. Default is 45 ml/min.  Set by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.

NOZ  Number of nozzles in zone last misted

TOL  Error tolerance in nozzle circuit flow rate.  Default is 80%.  See Adjusting Error Tolerance in Section 3.

CF  Full cartridge volume (in milliliters)

CR  Remaining cartridge volume (in milliliters)

DS  Dose volume (in milliliters)

MIX  Current insecticide MIX ratio, expressed in Parts Water:Parts Insecticide

DUE  Days Until Empty.  Remaining volume in cartridge, expressed in days of use until empty (Based on 14 day moving average consumption.  DUE reflecting first 14 days use will be inaccurate.)

HLD  Time (in 0.1 seconds) that agitation valve is held open at end of mist cycle to allow pressure to decrease.  May be changed by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.

* Reset by pushing Green ► button until value shows zero.
* PAN, FR and NR menu items are for iMistAway Module configuration.
* J, K and L menu items are for factory configuration only.