by homerjon_mistaway | Dec 31, 1969 | Gen 3 – Setup
Leak Detection enables the Gen 3 to detect a leak in the nozzle circuit. To function properly, the leak TOLerance should be calibrated to reflect the number of nozzles on the nozzle circuit. To configure Leak Detection TOLerance for Nozzle Count DATA Menu, TOL. Press...
by homerjon_mistaway | Dec 31, 1969 | Gen 1.3 - Troubleshooting
What is ERR3: ERR3 is displayed when the actual MIST volume is significantly greater than the target volume. Most Common Cause: leak in the nozzle circuit. Other Potential Causes: There are more nozzles installed in the nozzle circuit than entered as the NOZ count in...
by homerjon_mistaway | Dec 31, 1969 | Gen 1.3 – Setup
Leak Detection is an option – usually factory installed: Enables Gen 1.3 to detect a leak in the nozzle circuit and suspend misting. Enables Gen 1.3 to accurately report the level of remaining solution in the drum See Gen 1.3: Level Display Required to enable...
by homerjon_mistaway | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR3? ERR3 is displayed when the batch tank fill volume is significantly greater than expected. Most Common Cause: leak in the nozzle circuit. Other Potential Causes: System Setup does not reflect installed system – 1) more nozzles installed than...