Gen 3 Controller: Menus
Gen 3 SET-UP MENU
REM Set the duration for mists triggered by the remote transmitter. (Values from OFF to 120 seconds)
LRN Program unit to recognize a specific remote transmitter.
- Hold down Green ► button for 5 seconds and wait for countdown to begin.
- Press and hold any button on the remote transmitter.
- When DONE flashes in the display, the transmitter is programmed.
MAN* Set the duration for mists triggered by a MANUAL MIST
NOZ* Set the Number of nozzles in the circuit attached to the unit. If Zone Kit installed, there are separate displays for NZ1 and NZ2.
AGT Set duration for agitation sequence prior to each AUTO mist. Set time of once daily off-cycle agitation.
RAG Set duration for agitation prior to each REMOTE mist.
SEN Turn (optional) wind sensor ON or OFF
WND Set max wind speed (above which wind sensor reading inhibits mist.)
ALT Set time (in seconds) that (optional) external alarm will sound prior to each scheduled and remote mist
ER0 Enable or disable ERRor Code 0. Default is ON
ER2 Enable or disable ERRor Code 2. Default is OFF
ER3 Enable or disable ERRor Code 3. Default is ON
ER6 Enable or disable ERRor Code 6. Default is ON
FM Set flow meter type Brass (brS) or Plastic (PLS). Systems with serial numbers 403183 and higher are brass.
* For systems with zone kit installed, see Gen 3 Option: Zone Kit
Gen 3 MAINTENANCE MENU
REFILL “Virtually” fill the insecticide bottle. Holding Green ► button for 5 seconds triggers routine that prompts user for insecticide/water MIX ratio, bottle size (in ounces), LEVEL of concentrate in bottle.
DRN Drain. Unit will mist until batch tank is empty and pressure falls. Hold Green ► button for 5 seconds to trigger.
INS Unit is in Inspection Mode.
- Unit will fill with water and then mist for 5 minutes (refilling as necessary) without adding insecticide.
- Hold Green ► button for 5 seconds to trigger. If a Zone Kit is installed, there are separate inspection menus, INS1 and INS2.
CHG Adds a full charge of concentrate to the batch tank. Holding Green ► button for 5 seconds initiates an extended DOSE routine which brings the full batch of fresh water to its target MIX ratio.
WINT Winterizing step which holds inlet supply valve and agitation valve open for 30 seconds to allow any remaining trapped fluid to drain. Hold Green ► button for 5 seconds to trigger.
FLT Float switch diagnostic. Displays “dn” if float switch is not positioned at top of travel. Displays “UP” if it is. See Gen 3: Float Switch Test
FL tst Flowmeter Diagnostic. Holding Green ► button triggers routine that determines whether flow of water to the unit is normal and whether flowmeter is working as it should. See Gen 3: Flowmeter Test
Gen 3 DATA MENU
DM Daily Mist time (cumulative, in seconds)
MX Maximum Daily Mist allowed (in seconds)
TMC Total Mist Cycles since last reset* (*Reset by pressing Green ► button until value shows zero.)
TMM Total Mist Minutes since last reset*
MMC MANUAL MIST Cycles since last reset*
RMC REMOTE MIST Cycles since last reset*
TMH Total Mist Hours on unit. May not be reset.
PRH Cumulative dosing pump run time in hours. May not be reset.
SPD Wind speed as read by sensor
FL Batch tank fill volume (in milliliters) following last mist
AFR Average flow rate per nozzle in last zone misted (ml/min)
TF Target fill volume (in milliliters)
NFR Flow rate of average nozzle in circuit (in ml/min). Used in error condition calculations. Default is 45 ml/min. Set by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.
NOZ Number of nozzles in zone last misted
TOL Error tolerance in nozzle circuit flow rate. Default is 80%. See Adjusting Error Tolerance in Section 3.
CF Full cartridge volume (in milliliters)
CR Remaining cartridge volume (in milliliters)
DS Dose volume (in milliliters)
MIX Current insecticide MIX ratio, expressed in Parts Water:Parts Insecticide
DUE Days Until Empty. Remaining volume in cartridge, expressed in days of use until empty (Based on 14 day moving average consumption. DUE reflecting first 14 days use will be inaccurate.)
HLD Time (in 0.1 seconds) that agitation valve is held open at end of mist cycle to allow pressure to decrease. May be changed by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.